Electrodynamic Shaker table for Vibration Test of Cells and Batteries SAE J2464

  • 1
  • 2

Brand Name : LABTONE

Model Number : EV206

Certification : CE / ISO

Place of Origin : Dongguang, China

MOQ : 1 Set

Price : Negotiable

Payment Terms : T/T, L/C

Supply Ability : 15 Sets / Month

Delivery Time : 45 Working Days

Packaging Details : Plywood Case with Vacuum Packing

Sine Force : 600 kg

Max. Velocity : 200 cm/s

Maximum Displacement : 50 mm

Moving Element Mass : 6 kg

Payload : 200 kg

Power Amplifier : 3-phase AC 380V 50Hz

Contact Now

Electrodynamic Shaker table for Vibration Test of Cells and Batteries SAE J2464

Dynamic Shaker vibration testing Machine​ simulates the vibration environment under the laboratory condition, and test the impact strength as well as reliability of various vibration test applications. In the laboratory, with the aid of vibration testing system, model simulation of reproduction of sinusoidal, random, resonant search and dwell, classical shock and road simulation, etc. can be achieved. It is essential for product quality assurance, new product research and development.

Force = Mass x Acceleration (F = MA)

In general, the selection of a vibration system requires application of Newton’s Second Law of Motion: Force = Mass x Acceleration (F = MA). But this basic formula is only a starting point. It may be instructive to describe one example of an incorrect approach to estimating the required system force rating.

Example: “I have a 50 lb test specimen that must be tested @ 10 g. Therefore, I need a vibration system rated at 50 x 10 = 500 lbs force.”

After reviewing the following technical discussion you will have a better understanding of why this estimate of system force is incorrect

System Force Rating

Vibration systems have output force ratings typically expressed in terms of:

  • Sine force: lbs (kN) pk
  • Random Force: lbs (kN) rms
  • Shock Force: lbs (kN) pk

The stated random force rating assumes a certain spectrum shape (usually flat) over a given frequency range (usually 20 Hz – 2,000 Hz) and a certain minimum mass load on the shaker. If these conditions are different from your test requirements, a new calculation of the effective random force rating may be necessary. These output force ratings provide a starting point for the Force (F) parameter in F = MA.

Test Requirements

  • Test types:
  • Sine
  • Resonance dwell
  • Random
  • Shock
  • SRS shock
  • Mixed mode (Sine on Random, Random on Random)
  • Time replication
  • Test magnitude
  • Test frequency range
  • Test duration
  • Three axis testing requirement
    • Product orientation with respect to gravity

Working Principle:

Electrodynamic Shaker table for Vibration Test of Cells and Batteries SAE J2464

Specifications:

Model EV103 EV203 EV106 EV206 EV210 EV220 EV232 EV240 EV250 EV260
Frequency Range(Hz) 2-4000 2-2500 2-3000 2-3000 2-3000 2-2500 2-2500 2-2500 2-2500 2-2500
Max.Force(kg.f)

300

(2.94kN)

300

(2.94kN)

600

(5.88kN)

600

(5.88kN)

1000

(9.8kN)

2000

(19.6kN)

3200

(31.36kN)

4000

(39.2kN)

5000

(49kN)

6000

(58.8kN)

Max.Displacement

(mmp-p)

25 38 25 50 50 50 50 50 50 50

Max.Acceleration

(g)

100 100 100 100 100 100 100 100 100 100
Max.Velocity(cm/s) 200 200 200 200 200 200 200 200 200 200
Max.Load(kg) 110 120 200 200 300 400 500 800 1000 1000
Vibrator Model VG300/25 VG300/40 VG600/25 VG600/50 VG1000/50 VG2000/50 VG3200/50 VG4000/50 VG5000/50 VG6000/50
Armature Weight(kg) 3 3 6 6 10 20 30 40 50 50
Armature Dia.(mm) ¢150 ¢150 ¢200 ¢200 ¢240 ¢320 ¢400 ¢400 ¢450 ¢450
Cooling Method Forced Air Cooling
Vibrator Weight(kg) 460 460 720 920 1100 1600 2000 2500 3500 3800

Customer Services

In-Sales:

  • Customer communication and progress report.
  • Guidance for pre-installation preparation, equipment commissioning and test run.
  • Calibration (when Third Party’s verification is required).

After-Sales:

  • Technical training: operation of equipment, daily maintenance, common fault diagnosis and troubleshooting.
  • Scheduled on-site service: Detection of problem as soon as possible in order to eliminate equipment and anthropogenic hazards. This is to ensure long term and stable equipment operation as well as delivery of latest technical information.
  • Technical support: special paid services are provided according to customer’s needs.

  • 1,12 months warranty, lifelong maintenance. If any quality problems on our side occured in this period. we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-conference. If customers require on-site service,the transport and travel expense shall be borne by customer.

    2,Help choose right model with series of service

    3,Customization service-OEM,Design service,Buyer lable

    4,Cooperate with measuring if need the third party verification

Electrodynamic Shaker table for Vibration Test of Cells and Batteries SAE J2464


Product Tags:

electrodynamic vibration shaker system

      

vibration testing equipment

      
Wholesale Electrodynamic Shaker table for Vibration Test of Cells and Batteries SAE J2464 from china suppliers

Electrodynamic Shaker table for Vibration Test of Cells and Batteries SAE J2464 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Labtone Test Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)